EAGLE MM SC/TX |
|
| |
Reference product |
|
| Product description |
| Description |
Industrial Firewall/VPN System |
|
| Modi |
Router, Single Client Transparent (SCT) and Multi Client Transparent (MCT), PPPoE, PPTP |
|
| Port type and quantity |
Trusted Port: 1 x 100BASE-FX, MM-cable, SC-socket Untrusted Port: 1 x 10/100BASE-TX, TP-cable, RJ45-socket, autocrossing, autonegotiation, autopolarity |
|
| Type |
EAGLE MM SC/TX |
|
| Order No. |
943 011-005 |
|
| More Interfaces |
| Power supply/signaling contact |
1 plug-in terminal block, 6-pin |
|
| V.24 interface |
1 x RJ11 socket |
|
| Network size - length of cable |
| Twisted pair (TP) |
0 - 100 m |
|
| Multimode fiber (MM) 50/125 µm |
0 - 5000 m, 8 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km |
|
| Multimode fiber (MM) 62.5/125 µm |
0 - 4000 m, 11 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km |
|
| Security |
| Stateful inspection firewall |
firewallrules (incoming/outgoing, modem access, management), IP masquerading, 1-to-1 NAT, ARP limiter, MAC filter |
|
| Multipoint VPN |
IPSec, L2TP, DES, 3DES, AES (-128, -192, -256), Pre-Shared Key, X.509v3 certificate, MD5, SHA-1, NAT-T, firewall rules for every VPN connection |
|
| Antivirus protection |
Kaspersky anti virus engine (HTTP, FTP, POP3, SMTP) |
|
| Power requirements |
| Operating voltage |
24 V DC (-25% to +30%) |
|
| Current consumption at 24 V DC |
max. 350 mA |
|
| Service |
| Diagnostics |
LEDs (power, link status, data, error, ACA) signaling contact (24 V DC / 1 A), logfile |
|
| Configuration |
Command Line Interface (CLI), web interface, auto configuration adapter (ACA11), HiDiscovery, SolSoft policy server (ISCM) |
|
| Other services |
DHCP server/client, DHCP Relay/Option 82, DynDNS, firewall access via V.24 (PPP), NTP, VLAN support (IEEE 802.3pQ), port forwarding |
|
|
serial, HTTPS, SSH, SNMP V1/V2/V3, LLDP (HiVision/ Industrial HiVision) |
|
| Redundancy |
| Redundancy functions |
use in redundant net-/ringcoupling, dual homing, firewall redundancy (VRRP), redundant 24 V power supply |
|
| Ambient conditions |
| Operating temperature |
0 ºC to +55 ºC |
|
| Storage/transport temperature |
-40 ºC to +80 ºC |
|
| Relative humidity (non-condensing) |
10% to 95% |
|
| MTBF |
26.5 years; MIL-HDBK 217F: Gb 25 ºC |
|
| Mechanical construction |
| Dimensions (W x H x D) |
47 mm x 131 mm x 111 mm |
|
| Mounting |
DIN Rail 35 mm |
|
| Weight |
340 g |
|
| Protection class |
IP 20 |
|
| Mechanical stability |
| IEC 60068-2-27 shock |
15 g, 11 ms duration, 18 shocks |
|
| IEC 60068-2-6 vibration |
1 mm, 2 Hz - 13,2 Hz, 90 min.; 0,7g, 13,2 Hz - 100 Hz, 90 min.; 3,5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min |
|
| EMC interference immunity |
| EN 61000-4-2 electrostatic discharge (ESD) |
6 kV contact discharge, 8 kV air discharche |
|
| EN 61000-4-3 electromagnetic field |
10 V/m (80 - 2000 MHz) |
|
| EN 61000-4-4 fast transients (burst) |
2 kV power line, 1 kV data line |
|
| EN 61000-4-5 surge voltage |
power line: 2 kV (linie/earth), 1 kV (linie/line), 1 kV data line |
|
| EN 61000-4-6 conducted immunity |
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) |
|
| EMC emitted immunity |
| FCC CFR47 Part 15 |
FCC CFR47 Part 15 Class A |
|
| EN 55022 |
EN 55022 Class A |
|
| Approvals |
| Safety of industrial control equipment |
cUL 508 in preparation |
|
| Hazardous locations |
cUL 1604 Class1 Div 2 in preparation |
|
| Germanischer Lloyd |
Germanischer Lloyd |
|
| Scope of delivery and accessories |
| Scope of delivery |
device, terminal block, operating instructions, CD-manual |
|
| Accessories to order separately |
rail power supply RPS 30, RPS 60 or RPS 120, terminal cable, modem cable, HiVision network management, auto-configuration adapter (ACA 11), 19" installation frame |
|