MACH 4000, modular, managed Industrial Backbone-Switch, Layer 2 Switch with Software Professional. ETHERNET (10 Mbit/s), Fast-ETHERNET (100 Mbit/s) and Gigabit-ETHERNET (1000 Mbit/s) |
|
|
|
|
|
|
|
Port type and quantity |
|
|
|
up to 48 Fast-ETHERNET and 4 Gigabit-ETHERNET ports, thereof up to 32 Fast-ETHERNET ports above media modules practicable, 4 Gigabit Combo ports and 16 x 10/100Mbit/s Fast-ETHERNET ports are integral installed |
|
|
|
|
|
|
|
Type |
|
|
|
MACH4002 48 4G-L2P |
|
|
|
|
|
|
|
Order No. |
|
|
|
943 859-101 |
|
|
|
|
|
|
|
More Interfaces |
|
|
|
|
|
|
|
|
|
|
|
Power supply/signaling contact |
|
|
|
1 plug-in terminal block, 4-pin |
|
|
|
|
|
|
|
V.24 interface |
|
|
|
1 x RJ11 socket |
|
|
|
|
|
|
|
USB interface |
|
|
|
1USB interface to connect auto-configuration adapter (ACA21-USB) |
|
|
|
|
|
|
|
Network size - cascadibility |
|
|
|
|
|
|
|
|
|
|
|
Line - / star topology |
|
|
|
any |
|
|
|
|
|
|
|
Ring structure (HIPER-Ring) |
|
|
|
Ring-converttime < 50 ms typ. at LWL |
|
|
|
|
|
|
|
Power requirements |
|
|
|
|
|
|
|
|
|
|
|
Operating voltage |
|
|
|
Power supply unit M4-S-xx or M4-Power Chassis with power supply unit please order separately |
|
|
|
|
|
|
|
Power consumption |
|
|
|
70 W (without media modules) |
|
|
|
|
|
|
|
Service |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
serial interface, web interface, SNMP V1/V2/V3, HiVision, file transfer SW HTTP/TFTP |
|
|
|
|
|
|
|
Diagnostics |
|
|
|
LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full-duplex, error, redundancy management, ring-port, LED-test), signal contact (24V DC / 1 A), syslog, logfile, RMON, port mirroring, Topology Discovery IEEE 802.1AB (LLDP) |
|
|
|
|
|
|
|
Configuration |
|
|
|
comand line interface (CLI), TELNET, BootP, DHCP, DHCP Option 82, HiDiscovery, auto-configuration adapter (ACA21-USB) |
|
|
|
|
|
|
|
Security |
|
|
|
port-security (MAC- and IP-adresses), access control to agent (VLAN/IP) authentication 802.1x |
|
|
|
|
|
|
|
Other services |
|
|
|
QoS 4 classes, priorisation (IEEE 802.1D/p), VLAN (IEEE 802.1Q), multicast (IGMP snooping/querier), broadcastlimiter, fast aging, flow control IEEE 802.3x, PTP client (Precision Time Protocol, IEEE 1588), SNTP (Simple Network Time Protocol) |
|
|
|
|
|
|
|
Prepared for |
|
|
|
TOS (Type of Service) Diff.-Serv, TOS-Prio-Mapping, protocol based VLANs, Traffic Shaping, MSTP-802.1s |
|
|
|
|
|
|
|
Redundancy |
|
|
|
|
|
|
|
|
|
|
|
Redundancy functions |
|
|
|
HIPER-ring (ring structure), RSTP IEEE 802.1D/w (rapid spanning tree protocol), redundant network/ring coupling (master/receiver functionality), redundant 24 V power supply by M4-Power basic device, redundant signal contact, link aggregaion dynamic and static (max. 7 trunks, 8 ports/trunk, LACP) |
|
|
|
|
|
|
|
Ambient conditions |
|
|
|
|
|
|
|
|
|
|
|
Operating temperature |
|
|
|
0 ºC to +50 ºC |
|
|
|
|
|
|
|
Storage/transport temperature |
|
|
|
-25 ºC to +70 ºC |
|
|
|
|
|
|
|
Relative humidity (non-condensing) |
|
|
|
10% to 95% |
|
|
|
|
|
|
|
MTBF |
|
|
|
28.6 years; MIL-HDBK 217F: Gb 25 ºC |
|
|
|
|
|
|
|
Mechanical construction |
|
|
|
|
|
|
|
|
|
|
|
Dimensions (W x H x D) |
|
|
|
480 mm x 88 mm x 435 mm |
|
|
|
|
|
|
|
Mounting |
|
|
|
19" control cabinet |
|
|
|
|
|
|
|
Weight |
|
|
|
7,5 kg |
|
|
|
|
|
|
|
Protection class |
|
|
|
IP 20 |
|
|
|
|
|
|
|
Mechanical stability |
|
|
|
|
|
|
|
|
|
|
|
IEC 60068-2-27 shock |
|
|
|
15 g, 11 ms duration, 18 shocks |
|
|
|
|
|
|
|
IEC 60068-2-6 vibration |
|
|
|
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7 g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min |
|
|
|
|
|
|
|
EMC interference immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 61000-4-2 electrostatic discharge (ESD) |
|
|
|
6 kV contact discharge, 8 kV air discharge |
|
|
|
|
|
|
|
EN 61000-4-3 electromagnetic field |
|
|
|
10 V/m (80 - 1000 MHz) |
|
|
|
|
|
|
|
EN 61000-4-4 fast transients (burst) |
|
|
|
2 kV power line, 1 kV data line |
|
|
|
|
|
|
|
EN 61000-4-5 surge voltage |
|
|
|
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
|
|
|
|
|
|
|
EN 61000-4-6 conducted immunity |
|
|
|
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) |
|
|
|
|
|
|
|
EMC emitted immunity |
|
|
|
|
|
|
|
|
|
|
|
FCC CFR47 Part 15 |
|
|
|
FCC CFR47 Part 15 Class A |
|
|
|
|
|
|
|
EN 55022 |
|
|
|
EN 55022 Class A |
|
|
|
|
|
|
|
Approvals |
|
|
|
|
|
|
|
|
|
|
|
Safety of industrial control equipment |
|
|
|
cUL 508 (E175531) pending |
|
|
|
|
|
|
|
Germanischer Lloyd |
|
|
|
pending |
|
|
|
|
|
|
|
Safety of information technology equipment |
|
|
|
cUL 60950 (E168643) pending |
|
|
|
|
|
|
|