|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MM2-2FLM4 |
|
|
|
|
|
|
|
|
|
|
Product description |
|
|
|
|
|
|
|
|
|
|
|
Description |
|
|
|
Media module for MICE Switches (MS...),
10BASE-FL multi-mode F/O |
|
|
|
|
|
|
|
Port type and quantity |
|
|
|
2 x 10BASE-FL, MM cables, ST (BFOC) sockets |
|
|
|
|
|
|
|
Type |
|
|
|
MM2-2FLM4 |
|
|
|
|
|
|
|
Order No. |
|
|
|
943 734-001 |
|
|
|
|
|
|
|
Network size - length of cable |
|
|
|
|
|
|
|
|
|
|
|
Multimode fiber (MM) 50/125 µm |
|
|
|
0 - 2300 m,
10 dB link budget at 850 nm,
A = 3 dB/km, 3 dB reserve, B = 400 MHz x km |
|
|
|
|
|
|
|
Multimode fiber (MM) 62.5/125 µm |
|
|
|
0 - 3100 m,
13 dB link budget at 850 nm,
A = 3.2 dB/km, 3 dB reserve, B = 200 MHz x km |
|
|
|
|
|
|
|
Power requirements |
|
|
|
|
|
|
|
|
|
|
|
Operating voltage |
|
|
|
power supply via the backplane of the MICE switch |
|
|
|
|
|
|
|
Power consumption |
|
|
|
2.6 W |
|
|
|
|
|
|
|
Service |
|
|
|
|
|
|
|
|
|
|
|
Diagnostics |
|
|
|
LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) |
|
|
|
|
|
|
|
Ambient conditions |
|
|
|
|
|
|
|
|
|
|
|
Operating temperature |
|
|
|
0 ºC to +55 ºC |
|
|
|
|
|
|
|
Storage/transport temperature |
|
|
|
-25 ºC to +70 ºC |
|
|
|
|
|
|
|
Relative humidity (non-condensing) |
|
|
|
10% to 95% |
|
|
|
|
|
|
|
MTBF |
|
|
|
75.9 years; MIL-HDBK 217F: Gb 25 ºC |
|
|
|
|
|
|
|
Mechanical construction |
|
|
|
|
|
|
|
|
|
|
|
Dimensions (W x H x D) |
|
|
|
38 mm x 134 mm x 77 mm |
|
|
|
|
|
|
|
Mounting |
|
|
|
DIN Rail 35 mm |
|
|
|
|
|
|
|
Weight |
|
|
|
170 g |
|
|
|
|
|
|
|
Protection class |
|
|
|
IP 20 |
|
|
|
|
|
|
|
Mechanical stability |
|
|
|
|
|
|
|
|
|
|
|
IEC 60068-2-27 shock |
|
|
|
15 g, 11 ms duration, 18 shocks |
|
|
|
|
|
|
|
IEC 60068-2-6 vibration |
|
|
|
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz,
10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
|
|
|
|
|
|
|
EMC interference immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 61000-4-2 electrostatic discharge (ESD) |
|
|
|
6 kV contact discharge, 8 kV air discharge |
|
|
|
|
|
|
|
EN 61000-4-3 electromagnetic field |
|
|
|
10 V/m (80 - 1000 MHz) |
|
|
|
|
|
|
|
EN 61000-4-4 fast transients (burst) |
|
|
|
2 kV power line, 1 kV data line |
|
|
|
|
|
|
|
EN 61000-4-5 surge voltage |
|
|
|
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
|
|
|
|
|
|
|
EN 61000-4-6 conducted immunity |
|
|
|
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) |
|
|
|
|
|
|
|
EMC emitted immunity |
|
|
|
|
|
|
|
|
|
|
|
FCC CFR47 Part 15 |
|
|
|
FCC CFR47 Part 15 Class A |
|
|
|
|
|
|
|
EN 55022 |
|
|
|
EN 55022 Class A |
|
|
|
|
|
|
|
Approvals |
|
|
|
|
|
|
|
|
|
|
|
Safety of industrial control equipment |
|
|
|
cUL 508 (E175531) |
|
|
|
|
|
|
|
Hazardous locations |
|
|
|
cUL 1604 Class 1 Div 2 (E203960) |
|
|
|
|
|
|
|
Safety of information technology equipment |
|
|
|
cUL 60950 (E168643) |
|
|
|
|
|
|
|
Germanischer Lloyd |
|
|
|
Germanischer Lloyd (43 109-02 HH) |
|
|
|
|
|
|
|
Scope of delivery and accessories |
|
|
|
|
|
|
|
|
|
|
|
Scope of delivery |
|
|
|
module, operating manual |
|
|
|
|
|
|
|
Accessories to order separately |
|
|
|
ML-MS2/MM labels |
|
|
|
|