Industrial Networking
FiberINTERFACES
Industrial Ethernet
Rail Family
MICE
Switches
ETHERNET / Fast-ETHERNET Media Modules
Realtime Modules
Gigabit ETHERNET Media Modules
Labelling sheet
EAGLE System
Wireless LAN
Rail Video
OCTOPUS System IP67
MACH 3000
MACH 4000
LION Control Room Switch
Network Management
System Accessories
Powerlink Router
OpenRail System
Hirschmann Networks
             
M-SFP-LX/LC
Product description
Description SFP Fiberoptic Gigabit Ethernet Transceiver for: MICE media modules, MM4-4TX/SFP and MM4-2TX/SFP, OpenRail RS30-Switches, MACH 4002 48+4G, SmartLION and GigaLION.
Port type and quantity 1 x 1000BASE-LX with LC connector
Type M-SFP-LX/LC
Order No. 943 015-001
Network size - length of cable
Multimode fiber (MM) 50/125 µm 0 - 550 m,
0 - 11 dB link budget at 1310 nm
A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 550 m,
0 - 11 dB link budget at 1310 nm
A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Single mode fiber (SM) 9/125 µm 0 m - 20 km,
0 - 11 dB link budget at 1310 nm
A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Power requirements
Operating voltage power supply via the media module
Power consumption 1 W
Service
Diagnostics optical input and output power, transceiver temperature
Ambient conditions
Operating temperature 0 ºC to +60 ºC
Storage/transport temperature -25 ºC to +70 ºC
Relative humidity (non-condensing) 10% to 95%
Mechanical construction
Dimensions (W x H x D) 20 mm x 18 mm x 50 mm
Mounting SFP
Weight 40 g
Protection class IP 20
Mechanical stability
IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz,
10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line
EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line
EN 61000-4-6 conducted immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A
EN 55022 EN 55022 Class A
Approvals
Safety of industrial control equipment cUL 508 (E175531)
Hazardous locations cUL 1604 Class 1 Div 2 (E203960)
Safety of information technology equipment cUL 60950 (E168643)
Germanischer Lloyd Germanischer Lloyd (43 109-02 HH)
Scope of delivery and accessories
Scope of delivery SFP module
Accessories to order separately media module MM4-4TX/SFP; order no: 943 010-001