MS4128-5
Product description
Description Power MICE, modular, managed Industrial ETHERNET Switch,
store and forward switching mode,
Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) and
Gigabit-Ethernet (1000 Mbit/s)
Port type and quantity up to 28 ports possible via media modules,
4 x 1000BASE-SX with SFP modules or 4 x 10/100/1000BASE-TX and
24 Fast-Ethernet (100 Mbit/s) ports
Type MS4128-5
Order No. 943 009-001
More Interfaces
Power supply/signaling contact 2 plug-in terminal block, 4-pin
V.24 interface 1 x RJ11 socket
Network size - cascadibility
Line - / star topology any
Ring structure (HIPER-Ring) 50 switches (ring recovery time < 50 msec typic with fiber)
Power requirements
Operating voltage 24 V DC (-25% to +30%)
Current consumption at 24 V DC 630 mA (not including media modules)
Power consumption 15 W (not including media modules)
Service
Diagnostics LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, error, redundancy manager, ring port, LED test),
cable tester,
2 x signal contact / fault relais (24 V DC / 1 A),
RMON (statistics, history, alarms, events),
port mirroring.
Configuration Comand Line Interface (CLI), TELNET, BootP, DHCP, DHCP option 82,
HIDiscovery, auto-configuration adapter (ACA21-USB)
Security ACL, Authentication (802.1x, port security, (SNMP V3 (SSH, SSL) in preparation)
Other services QoS 4 classes, prioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP), broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
Prepared for TOS (Type of Service) Diff.-Serv, TOS-Prio-Mapping, protocol based VLANs,
Routing RIP and OSPF HIRRP / VRRP, Proxy ARP
Redundancy
Redundancy functions HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol),
redundant network/ring coupling, dual homing,
redundant 24 V power supply, redundant signal contact,
link aggregation dynamic and static (max. 7 trunks, 8 ports/trunk, LACP)
Ambient conditions
Operating temperature 0 ºC to +60 ºC
Storage/transport temperature -25 ºC to +70 ºC
Relative humidity (non-condensing) 10% to 95%
MTBF 24.2 years; MIL-HDBK 217F: Gb 25 ºC
Mechanical construction
Dimensions (W x H x D) 315 mm x 134 mm x 140 mm
Mounting DIN Rail 35 mm
Weight 2,2 kg
Protection class IP 20
Mechanical stability
IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.;
3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line
EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A
EN 55022 EN 55022 Class A
Approvals
Safety of industrial control equipment cUL 508 (E175531) in preparation
Hazardous locations cUL 1604 Class 1 Div 2 (E203960) in preparation
Safety of information technology equipment cUL 60950 (E168643) in preparation
Germanischer Lloyd Germanischer Lloyd in preparation
Scope of delivery and accessories
Scope of delivery Device, terminal block, operating manual
Accessories to order separately ML-MS3 labels, MB-2T expansion backplane, auto-configuration adapter (ACA 21-USB),
HiVision network management, 19" installation, terminal cable,
rail power supply RPS 30, RPS 60 or RPS 120