|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MS4128-5 |
|
|
|
|
|
|
|
|
|
|
Product description |
|
|
|
|
|
|
|
|
|
|
|
Description |
|
|
|
Power MICE, modular, managed Industrial ETHERNET Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) and Gigabit-Ethernet (1000 Mbit/s) |
|
|
|
|
|
|
|
Port type and quantity |
|
|
|
up to 28 ports possible via media modules, 4 x 1000BASE-SX with SFP modules or 4 x 10/100/1000BASE-TX and 24 Fast-Ethernet (100 Mbit/s) ports |
|
|
|
|
|
|
|
Type |
|
|
|
MS4128-5 |
|
|
|
|
|
|
|
Order No. |
|
|
|
943 009-001 |
|
|
|
|
|
|
|
More Interfaces |
|
|
|
|
|
|
|
|
|
|
|
Power supply/signaling contact |
|
|
|
2 plug-in terminal block, 4-pin |
|
|
|
|
|
|
|
V.24 interface |
|
|
|
1 x RJ11 socket |
|
|
|
|
|
|
|
Network size - cascadibility |
|
|
|
|
|
|
|
|
|
|
|
Line - / star topology |
|
|
|
any |
|
|
|
|
|
|
|
Ring structure (HIPER-Ring) |
|
|
|
50 switches (ring recovery time < 50 msec typic with fiber) |
|
|
|
|
|
|
|
Power requirements |
|
|
|
|
|
|
|
|
|
|
|
Operating voltage |
|
|
|
24 V DC (-25% to +30%) |
|
|
|
|
|
|
|
Current consumption at 24 V DC |
|
|
|
630 mA (not including media modules) |
|
|
|
|
|
|
|
Power consumption |
|
|
|
15 W (not including media modules) |
|
|
|
|
|
|
|
Service |
|
|
|
|
|
|
|
|
|
|
|
Diagnostics |
|
|
|
LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, error, redundancy manager, ring port, LED test), cable tester, 2 x signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring. |
|
|
|
|
|
|
|
Configuration |
|
|
|
Comand Line Interface (CLI), TELNET, BootP, DHCP, DHCP option 82, HIDiscovery, auto-configuration adapter (ACA21-USB) |
|
|
|
|
|
|
|
Security |
|
|
|
ACL, Authentication (802.1x, port security, (SNMP V3 (SSH, SSL) in preparation) |
|
|
|
|
|
|
|
Other services |
|
|
|
QoS 4 classes, prioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP), broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x |
|
|
|
|
|
|
|
Prepared for |
|
|
|
TOS (Type of Service) Diff.-Serv, TOS-Prio-Mapping, protocol based VLANs, Routing RIP and OSPF HIRRP / VRRP, Proxy ARP |
|
|
|
|
|
|
|
Redundancy |
|
|
|
|
|
|
|
|
|
|
|
Redundancy functions |
|
|
|
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundant network/ring coupling, dual homing, redundant 24 V power supply, redundant signal contact, link aggregation dynamic and static (max. 7 trunks, 8 ports/trunk, LACP) |
|
|
|
|
|
|
|
Ambient conditions |
|
|
|
|
|
|
|
|
|
|
|
Operating temperature |
|
|
|
0 ºC to +60 ºC |
|
|
|
|
|
|
|
Storage/transport temperature |
|
|
|
-25 ºC to +70 ºC |
|
|
|
|
|
|
|
Relative humidity (non-condensing) |
|
|
|
10% to 95% |
|
|
|
|
|
|
|
MTBF |
|
|
|
24.2 years; MIL-HDBK 217F: Gb 25 ºC |
|
|
|
|
|
|
|
Mechanical construction |
|
|
|
|
|
|
|
|
|
|
|
Dimensions (W x H x D) |
|
|
|
315 mm x 134 mm x 140 mm |
|
|
|
|
|
|
|
Mounting |
|
|
|
DIN Rail 35 mm |
|
|
|
|
|
|
|
Weight |
|
|
|
2,2 kg |
|
|
|
|
|
|
|
Protection class |
|
|
|
IP 20 |
|
|
|
|
|
|
|
Mechanical stability |
|
|
|
|
|
|
|
|
|
|
|
IEC 60068-2-27 shock |
|
|
|
15 g, 11 ms duration, 18 shocks |
|
|
|
|
|
|
|
IEC 60068-2-6 vibration |
|
|
|
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
|
|
|
|
|
|
|
EMC interference immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 61000-4-2 electrostatic discharge (ESD) |
|
|
|
6 kV contact discharge, 8 kV air discharge |
|
|
|
|
|
|
|
EN 61000-4-3 electromagnetic field |
|
|
|
10 V/m (80 - 1000 MHz) |
|
|
|
|
|
|
|
EN 61000-4-4 fast transients (burst) |
|
|
|
2 kV power line, 1 kV data line |
|
|
|
|
|
|
|
EN 61000-4-5 surge voltage |
|
|
|
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
|
|
|
|
|
|
|
EN 61000-4-6 conducted immunity |
|
|
|
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) |
|
|
|
|
|
|
|
EMC emitted immunity |
|
|
|
|
|
|
|
|
|
|
|
FCC CFR47 Part 15 |
|
|
|
FCC CFR47 Part 15 Class A |
|
|
|
|
|
|
|
EN 55022 |
|
|
|
EN 55022 Class A |
|
|
|
|
|
|
|
Approvals |
|
|
|
|
|
|
|
|
|
|
|
Safety of industrial control equipment |
|
|
|
cUL 508 (E175531) in preparation |
|
|
|
|
|
|
|
Hazardous locations |
|
|
|
cUL 1604 Class 1 Div 2 (E203960) in preparation |
|
|
|
|
|
|
|
Safety of information technology equipment |
|
|
|
cUL 60950 (E168643) in preparation |
|
|
|
|
|
|
|
Germanischer Lloyd |
|
|
|
Germanischer Lloyd in preparation |
|
|
|
|
|
|
|
Scope of delivery and accessories |
|
|
|
|
|
|
|
|
|
|
|
Scope of delivery |
|
|
|
Device, terminal block, operating manual |
|
|
|
|
|
|
|
Accessories to order separately |
|
|
|
ML-MS3 labels, MB-2T expansion backplane, auto-configuration adapter (ACA 21-USB), HiVision network management, 19" installation, terminal cable, rail power supply RPS 30, RPS 60 or RPS 120 |
|
|
|
|