OCTOPUS 5TX |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Product description |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Description |
 |
 |
 |
IP67 switch in accordance
with IEEE 802.3, store and forward switching mode, ETHERNET (10 Mbit/s)
and Fast-ETHERNET (100 Mbit/s) |
 |
 |
 |
 |
 |
 |
 |
Port type and quantity |
 |
 |
 |
5 x 10/100 BASE-TX,
M12 D coding, 4-pole, 2-pair TP cable auto-crossing, auto-negotiation,
auto-polarity |
 |
 |
 |
 |
 |
 |
 |
Type |
 |
 |
 |
OCTOPUS 5TX |
 |
 |
 |
 |
 |
 |
 |
Order No. |
 |
 |
 |
943 844-001 |
 |
 |
 |
 |
 |
 |
 |
More Interfaces |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Power supply/signaling contact |
 |
 |
 |
1 M12 A coding 5-pole
/ no signal contact (fault relais) |
 |
 |
 |
 |
 |
 |
 |
Network size
- length of cable |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Twisted pair (TP) |
 |
 |
 |
0 - 100 m |
 |
 |
 |
 |
 |
 |
 |
Network size
- cascadibility |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Line - / star topology |
 |
 |
 |
any |
 |
 |
 |
 |
 |
 |
 |
Power requirements |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating voltage |
 |
 |
 |
24 V DC (-25% to +30%) |
 |
 |
 |
 |
 |
 |
 |
Power consumption |
 |
 |
 |
max. 2,4 W |
 |
 |
 |
 |
 |
 |
 |
Service |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Diagnostics |
 |
 |
 |
LEDs (power, link
status, data) |
 |
 |
 |
 |
 |
 |
 |
Ambient conditions |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating temperature |
 |
 |
 |
0 ºC to +60 ºC |
 |
 |
 |
 |
 |
 |
 |
Storage/transport temperature |
 |
 |
 |
-25 ºC to +70 ºC |
 |
 |
 |
 |
 |
 |
 |
MTBF |
 |
 |
 |
143.6 years; MIL-HDBK
217F: Gb 25 ºC |
 |
 |
 |
 |
 |
 |
 |
Mechanical construction |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Dimensions (W x H x D) |
 |
 |
 |
60 mm x 126 mm x 31
mm |
 |
 |
 |
 |
 |
 |
 |
Mounting |
 |
 |
 |
wall mounting |
 |
 |
 |
 |
 |
 |
 |
Weight |
 |
 |
 |
210 g |
 |
 |
 |
 |
 |
 |
 |
Protection class |
 |
 |
 |
IP 67 |
 |
 |
 |
 |
 |
 |
 |
Mechanical stability |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
IEC 60068-2-27 shock |
 |
 |
 |
15 g, 11 ms duration,
18 shocks |
 |
 |
 |
 |
 |
 |
 |
IEC 60068-2-6 vibration |
 |
 |
 |
3.5 mm, 3 Hz - 9 Hz,
10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
 |
 |
 |
 |
 |
 |
 |
EMC interference
immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-2 electrostatic
discharge (ESD) |
 |
 |
 |
4 kV contact discharge,
8 kV air discharge |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-3 electromagnetic
field |
 |
 |
 |
10 V/m (80 - 1000
MHz) |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-4 fast transients
(burst) |
 |
 |
 |
2 kV power line, 1
kV data line |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-5 surge voltage |
 |
 |
 |
power line: 2kV (linie/earth),
1 kV (linie/line), 1 kV data line |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-6 conducted immunity |
 |
 |
 |
10 V (150 kHz - 80
MHz) |
 |
 |
 |
 |
 |
 |
 |
EMC emitted
immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
FCC CFR47 Part 15 |
 |
 |
 |
FCC CFR47 Part 15
Class A |
 |
 |
 |
 |
 |
 |
 |
EN 55022 |
 |
 |
 |
EN 55022 Class A |
 |
 |
 |
 |
 |
 |
 |
Approvals |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Safety of industrial control
equipment |
 |
 |
 |
cUL 508 ( E175537)
in preparation |
 |
 |
 |
 |
 |
 |
 |
Scope of delivery
and accessories |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Scope of delivery |
 |
 |
 |
2 x covers for sealing
unused ports labels, description and operating instructions |
 |
 |
 |
 |
 |
 |
 |
Accessories to order separately |
 |
 |
 |
M12 connector EM12S
OCTOPUS, order no. 934 445-001 patchcords EM12S 001Lxxxx OCTOPUS,
order no. 934 497-xxx Bulkhead M12 to RJ45 EF12RJ45 OCTOPUS; order
no. 934 498-001 |
 |
 |
 |
 |