RS2-4TX/1FX-SM |
|
|
|
|
|
|
|
|
|
|
Product description |
|
|
|
|
|
|
|
|
|
|
|
Description |
|
|
|
unmanaged Industrial
ETHERNET Rail-Switch, store and forward switching mode, Ethernet (10
Mbit/s) and Fast-Ethernet (100 Mbit/s) |
|
|
|
|
|
|
|
Port type and quantity |
|
|
|
4 x 10/100BASE-TX,
TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,
1 x 100BASE-FX, SM cable, SC sockets |
|
|
|
|
|
|
|
Type |
|
|
|
RS2-4TX/1FX-SM |
|
|
|
|
|
|
|
Order No. |
|
|
|
943 770-001 |
|
|
|
|
|
|
|
More Interfaces |
|
|
|
|
|
|
|
|
|
|
|
Power supply/signaling contact |
|
|
|
1 plug-in terminal
block, 5-pin |
|
|
|
|
|
|
|
Network size
- length of cable |
|
|
|
|
|
|
|
|
|
|
|
Twisted pair (TP) |
|
|
|
0 - 100 m |
|
|
|
|
|
|
|
Single mode fiber (SM) 9/125
µm |
|
|
|
0 - 32.5 km, 16 dB
link budget at 1300 nm, A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm
x km) |
|
|
|
|
|
|
|
Network size
- cascadibility |
|
|
|
|
|
|
|
|
|
|
|
Line - / star topology |
|
|
|
any |
|
|
|
|
|
|
|
Power requirements |
|
|
|
|
|
|
|
|
|
|
|
Operating voltage |
|
|
|
24 V DC (-25% to +30%) |
|
|
|
|
|
|
|
Current consumption at 24
V DC |
|
|
|
max. 200 mA |
|
|
|
|
|
|
|
Service |
|
|
|
|
|
|
|
|
|
|
|
Diagnostics |
|
|
|
LEDs (power, link
status, data, error), signal contact / fault relais (24 V DC / 1 A) |
|
|
|
|
|
|
|
Redundancy |
|
|
|
|
|
|
|
|
|
|
|
Redundancy functions |
|
|
|
redundant 24 V power
supply |
|
|
|
|
|
|
|
Ambient conditions |
|
|
|
|
|
|
|
|
|
|
|
Operating temperature |
|
|
|
0 °C to +60 °C |
|
|
|
|
|
|
|
Storage/transport temperature |
|
|
|
-25 °C to +70 °C |
|
|
|
|
|
|
|
Relative humidity (non-condensing) |
|
|
|
10% to 95% |
|
|
|
|
|
|
|
MTBF |
|
|
|
65.9 years; MIL-HDBK
217F: Gb 25 ° |
|
|
|
|
|
|
|
Mechanical construction |
|
|
|
|
|
|
|
|
|
|
|
Dimensions (W x H x D) |
|
|
|
47 mm x 135 mm x 111
mm |
|
|
|
|
|
|
|
Mounting |
|
|
|
DIN Rail 35 mm |
|
|
|
|
|
|
|
Weight |
|
|
|
320 g |
|
|
|
|
|
|
|
Protection class |
|
|
|
IP 20 |
|
|
|
|
|
|
|
Mechanical stability |
|
|
|
|
|
|
|
|
|
|
|
IEC 60068-2-27 shock |
|
|
|
15 g, 11 ms duration,
18 shocks |
|
|
|
|
|
|
|
IEC 60068-2-6 vibration |
|
|
|
1 mm, 2 Hz - 13.2
Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz,
10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
|
|
|
|
|
|
|
EMC interference
immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 61000-4-2 electrostatic
discharge (ESD) |
|
|
|
6 kV contact discharge,
8 kV air discharge |
|
|
|
|
|
|
|
EN 61000-4-3 electromagnetic
field |
|
|
|
10 V/m (80 - 1000
MHz) |
|
|
|
|
|
|
|
EN 61000-4-4 fast transients
(burst) |
|
|
|
2 kV power line, 1
kV data line |
|
|
|
|
|
|
|
EN 61000-4-5 surge voltage |
|
|
|
power line: 2 kV (line/earth),
1 kV (line/line), 1 kV data line |
|
|
|
|
|
|
|
EN 61000-4-6 conducted immunity |
|
|
|
3 V (10 kHz - 150
kHz), 10 V (150 kHz - 80 MHz) |
|
|
|
|
|
|
|
EMC emitted
immunity |
|
|
|
|
|
|
|
|
|
|
|
FCC CFR47 Part 15 |
|
|
|
FCC CFR47 Part 15
Class A |
|
|
|
|
|
|
|
EN 55022 |
|
|
|
EN 55022 Class A |
|
|
|
|
|
|
|
Approvals |
|
|
|
|
|
|
|
|
|
|
|
Safety of industrial control
equipment |
|
|
|
cUL 508 (E175531) |
|
|
|
|
|
|
|
Hazardous locations |
|
|
|
cUL 1604 Class 1 Div
2 (E203960) |
|
|
|
|
|
|
|
Safety of information technology
equipment |
|
|
|
cUL 60950 (E168643) |
|
|
|
|
|
|
|
Germanischer Lloyd |
|
|
|
Germanischer Lloyd
(15 662 - 00 HH) |
|
|
|
|
|
|
|
Scope of delivery
and accessories |
|
|
|
|
|
|
|
|
|
|
|
Scope of delivery |
|
|
|
device, terminal block,
operating manual |
|
|
|
|
|
|
|
Accessories to order separately |
|
|
|
rail power supply