Entry Level Industrial ETHERNET Rail Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) |
 |
 |
 |
 |
 |
 |
 |
Port type and quantity |
 |
 |
 |
4 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity 1 x 100BASE-FX, MM cables, SC sockets |
 |
 |
 |
 |
 |
 |
 |
Type |
 |
 |
 |
SPIDER 4TX/1FX |
 |
 |
 |
 |
 |
 |
 |
Order No. |
 |
 |
 |
943 221-001 |
 |
 |
 |
 |
 |
 |
 |
More Interfaces |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Power supply/signaling contact |
 |
 |
 |
1 plug-in terminal block, 3-pin, no signal contact |
 |
 |
 |
 |
 |
 |
 |
Network size - length of cable |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Twisted pair (TP) |
 |
 |
 |
0 - 100 m |
 |
 |
 |
 |
 |
 |
 |
Multimode fiber (MM) 50/125 µm |
 |
 |
 |
0 - 5000 m, 8 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km |
 |
 |
 |
 |
 |
 |
 |
Multimode fiber (MM) 62.5/125 µm |
 |
 |
 |
0 - 4000 m, 11 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km |
 |
 |
 |
 |
 |
 |
 |
Network size - cascadibility |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Line - / star topology |
 |
 |
 |
Any |
 |
 |
 |
 |
 |
 |
 |
Power requirements |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating voltage |
 |
 |
 |
9,6 V DC - 32 V DC |
 |
 |
 |
 |
 |
 |
 |
Current consumption at 24 V DC |
 |
 |
 |
Max. 150 mA |
 |
 |
 |
 |
 |
 |
 |
Power consumption |
 |
 |
 |
Max. 3,9 W 13,3 Btu (IT)/h at 24 V DC |
 |
 |
 |
 |
 |
 |
 |
Service |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Diagnostics |
 |
 |
 |
LEDs (power, link status, data, data rate) |
 |
 |
 |
 |
 |
 |
 |
Ambient conditions |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating temperature |
 |
 |
 |
0 ºC to +60 ºC |
 |
 |
 |
 |
 |
 |
 |
Storage/transport temperature |
 |
 |
 |
-40 ºC to +70 ºC |
 |
 |
 |
 |
 |
 |
 |
Relative humidity (non-condensing) |
 |
 |
 |
10% to 95% |
 |
 |
 |
 |
 |
 |
 |
MTBF |
 |
 |
 |
112.0 years; MIL-HDBK 217F: Gb 25 ºC |
 |
 |
 |
 |
 |
 |
 |
Mechanical construction |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Dimensions (W x H x D) |
 |
 |
 |
25 mm x 114 mm x 79 mm |
 |
 |
 |
 |
 |
 |
 |
Mounting |
 |
 |
 |
DIN Rail 35 mm |
 |
 |
 |
 |
 |
 |
 |
Weight |
 |
 |
 |
120 g |
 |
 |
 |
 |
 |
 |
 |
Protection class |
 |
 |
 |
IP 30 |
 |
 |
 |
 |
 |
 |
 |
Mechanical stability |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
IEC 60068-2-27 shock |
 |
 |
 |
15 g, 11 ms duration, 18 shocks |
 |
 |
 |
 |
 |
 |
 |
IEC 60068-2-6 vibration |
 |
 |
 |
3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
 |
 |
 |
 |
 |
 |
 |
EMC interference immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-2 electrostatic discharge (ESD) |
 |
 |
 |
6 kV contact discharge, 8 kV air discharge |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-3 electromagnetic field |
 |
 |
 |
10 V/m (80 - 1000 MHz) |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-4 fast transients (burst) |
 |
 |
 |
2 kV power line, 4 kV data line |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-5 surge voltage |
 |
 |
 |
Power line: 2 kV (linie/earth), 1 kV (linie/line), 1 kV data line |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-6 conducted immunity |
 |
 |
 |
10 V (150 kHz - 80 kHz) |
 |
 |
 |
 |
 |
 |
 |
EMC emitted immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
FCC CFR47 Part 15 |
 |
 |
 |
FCC CFR47 Part 15 Class A |
 |
 |
 |
 |
 |
 |
 |
EN 55022 |
 |
 |
 |
EN 55022 Class A |
 |
 |
 |
 |
 |
 |
 |
Approvals |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Safety of industrial control equipment |
 |
 |
 |
cUL 508 (E175531) |
 |
 |
 |
 |
 |
 |
 |
Scope of delivery and accessories |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Scope of delivery |
 |
 |
 |
Device, terminal block, operating manual |
 |
 |
 |
 |
 |
 |
 |
Accessories to order separately |
 |
 |
 |
Rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame |
 |
 |
 |
 |