RS2-16M 1SM SC |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Product description |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Description |
 |
 |
 |
Managed Industrial ETHERNET Rail Switch, store and forward switching mode,
Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) |
 |
 |
 |
 |
 |
 |
 |
Port type and quantity |
 |
 |
 |
15 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,
1 x 100BASE-FX, SM cables, SC sockets |
 |
 |
 |
 |
 |
 |
 |
Type |
 |
 |
 |
RS2-16M 1SM SC |
 |
 |
 |
 |
 |
 |
 |
Order No. |
 |
 |
 |
943 790-003 |
 |
 |
 |
 |
 |
 |
 |
More Interfaces |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Power supply/signaling contact |
 |
 |
 |
1 plug-in terminal block, 6-pin |
 |
 |
 |
 |
 |
 |
 |
V.24 interface |
 |
 |
 |
1 x RJ11 socket |
 |
 |
 |
 |
 |
 |
 |
Network size - length of cable |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Twisted pair (TP) |
 |
 |
 |
0 - 100 m |
 |
 |
 |
 |
 |
 |
 |
Single mode fiber (SM) 9/125 µm |
 |
 |
 |
0 - 32.5 km, 16 dB link budget at 1300 nm,
A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km) |
 |
 |
 |
 |
 |
 |
 |
Network size - cascadibility |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Line - / star topology |
 |
 |
 |
any |
 |
 |
 |
 |
 |
 |
 |
Ring structure (HIPER-Ring) |
 |
 |
 |
50 (reconfiguration time < 0.5 sec.) |
 |
 |
 |
 |
 |
 |
 |
Power requirements |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating voltage |
 |
 |
 |
24 V DC (-25% to +30%) |
 |
 |
 |
 |
 |
 |
 |
Current consumption at 24 V DC |
 |
 |
 |
max. 550 mA |
 |
 |
 |
 |
 |
 |
 |
Service |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Diagnostics |
 |
 |
 |
LEDs (power, link status, data, standby, redundancy manager),
signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events),
port mirroring. |
 |
 |
 |
 |
 |
 |
 |
Configuration |
 |
 |
 |
terminal SW, BOOTP, DHCP, DHCP option 82, auto-configuration adapter (ACA 11) |
 |
 |
 |
 |
 |
 |
 |
Security |
 |
 |
 |
port security (MAC based and IP based), SNMPv3 |
 |
 |
 |
 |
 |
 |
 |
Other services |
 |
 |
 |
prioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP), broadcastlimiter, SNTP (simple network time protocol), PTP (precision time protocol, IEEE 1588), flow control IEEE 802.3x |
 |
 |
 |
 |
 |
 |
 |
Redundancy |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Redundancy functions |
 |
 |
 |
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundant network/
ring coupling (master/receiver), dual homing (master/receiver), redundant 24 V power supply |
 |
 |
 |
 |
 |
 |
 |
Ambient conditions |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating temperature |
 |
 |
 |
0 °C to +60 °C |
 |
 |
 |
 |
 |
 |
 |
Storage/transport temperature |
 |
 |
 |
-25 °C to +70 °C |
 |
 |
 |
 |
 |
 |
 |
Relative humidity (non-condensing) |
 |
 |
 |
10% to 95% |
 |
 |
 |
 |
 |
 |
 |
MTBF |
 |
 |
 |
22 years; MIL-HDBK 217F: Gb 25 °C |
 |
 |
 |
 |
 |
 |
 |
Mechanical construction |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Dimensions (W x H x D) |
 |
 |
 |
110 mm x 131 mm x 111 mm |
 |
 |
 |
 |
 |
 |
 |
Mounting |
 |
 |
 |
DIN Rail 35 mm |
 |
 |
 |
 |
 |
 |
 |
Weight |
 |
 |
 |
650 g |
 |
 |
 |
 |
 |
 |
 |
Protection class |
 |
 |
 |
IP 20 |
 |
 |
 |
 |
 |
 |
 |
Mechanical stability |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
IEC 60068-2-27 shock |
 |
 |
 |
15 g, 11 ms duration, 18 shocks |
 |
 |
 |
 |
 |
 |
 |
IEC 60068-2-6 vibration |
 |
 |
 |
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz,
10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
 |
 |
 |
 |
 |
 |
 |
EMC interference immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-2 electrostatic discharge (ESD) |
 |
 |
 |
6 kV contact discharge, 8 kV air discharge |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-3 electromagnetic field |
 |
 |
 |
10 V/m (80 - 1000 MHz) |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-4 fast transients (burst) |
 |
 |
 |
2 kV power line, 1 kV data line |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-5 surge voltage |
 |
 |
 |
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-6 conducted immunity |
 |
 |
 |
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) |
 |
 |
 |
 |
 |
 |
 |
EMC emitted immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
FCC CFR47 Part 15 |
 |
 |
 |
FCC CFR47 Part 15 Class A |
 |
 |
 |
 |
 |
 |
 |
EN 55022 |
 |
 |
 |
EN 55022 Class A |
 |
 |
 |
 |
 |
 |
 |
Approvals |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Safety of industrial control equipment |
 |
 |
 |
cUL 508 (E175531) |
 |
 |
 |
 |
 |
 |
 |
Hazardous locations |
 |
 |
 |
cUL 1604 Class 1 Div 2 (E203960) |
 |
 |
 |
 |
 |
 |
 |
Germanischer Lloyd |
 |
 |
 |
Germanischer Lloyd (15 662 - 00 HH) |
 |
 |
 |
 |
 |
 |
 |
Scope of delivery and accessories |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Scope of delivery |
 |
 |
 |
device, terminal block, operating manual |
 |
 |
 |
 |
 |
 |
 |
Accessories to order separately |
 |
 |
 |
rail power supply RPS 30, RPS 60 or RPS 120, terminal cable, HiVision network management, auto-configuration adapter (ACA 11), 19" installation frame |
 |
 |
 |
 |
 |
 |
 |
Frontend Module |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Modulation |
 |
 |
 |
serial interface, web interface SNMP v1/v2/v3,