ACA 11 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Product description |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Description |
 |
 |
 |
The ACA 11 auto-configuration
adapter saves the configuration data of the connected switch. It enables
managed switched to be easily comissioned and quickly replaced. |
 |
 |
 |
 |
 |
 |
 |
Type |
 |
 |
 |
ACA 11 |
 |
 |
 |
 |
 |
 |
 |
Order No. |
 |
 |
 |
943 751-001 |
 |
 |
 |
 |
 |
 |
 |
More Interfaces |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
To the RS232 interface on
the switch |
 |
 |
 |
RJ11 connector |
 |
 |
 |
 |
 |
 |
 |
Power requirements |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating voltage |
 |
 |
 |
via the RS232 interface on the
switch |
 |
 |
 |
 |
 |
 |
 |
Service |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Diagnostics |
 |
 |
 |
writing to ACA, reading from ACA,
writing/reading not OK; (display using LEDs on the switch) |
 |
 |
 |
 |
 |
 |
 |
Configuration |
 |
 |
 |
via the RS232 interface of the
switch and via SNMP/Web |
 |
 |
 |
 |
 |
 |
 |
Ambient conditions |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating temperature |
 |
 |
 |
0 °C to +60 °C |
 |
 |
 |
 |
 |
 |
 |
Storage/transport temperature |
 |
 |
 |
-25 °C to +70 °C |
 |
 |
 |
 |
 |
 |
 |
Relative humidity (non-condensing) |
 |
 |
 |
10% to 95% |
 |
 |
 |
 |
 |
 |
 |
MTBF |
 |
 |
 |
370.9 years; MIL-HDBK 217F: Gb
25 °C |
 |
 |
 |
 |
 |
 |
 |
Mechanical construction |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Dimensions (W x H x D) |
 |
 |
 |
90 mm x 27 mm x 12 mm |
 |
 |
 |
 |
 |
 |
 |
Mounting |
 |
 |
 |
plug-in module |
 |
 |
 |
 |
 |
 |
 |
Weight |
 |
 |
 |
35 g |
 |
 |
 |
 |
 |
 |
 |
Protection class |
 |
 |
 |
IP 40 |
 |
 |
 |
 |
 |
 |
 |
Cable length |
 |
 |
 |
31.5 cm |
 |
 |
 |
 |
 |
 |
 |
Mechanical stability |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
IEC 60068-2-27 shock |
 |
 |
 |
15 g, 11 ms duration, 18 shocks |
 |
 |
 |
 |
 |
 |
 |
IEC 60068-2-6 vibration |
 |
 |
 |
1 g, 10 Hz - 150 Hz, 30 cycles |
 |
 |
 |
 |
 |
 |
 |
EMC interference
immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-2 electrostatic
discharge (ESD) |
 |
 |
 |
6 kV contact discharge, 8 kV air
discharge |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-3 electromagnetic
field |
 |
 |
 |
10 V/m |
 |
 |
 |
 |
 |
 |
 |
EMC emitted
immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
EN 55022 |
 |
 |
 |
EN 55022 |
 |
 |
 |
 |
 |
 |
 |
Approvals |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Safety of industrial control
equipment |
 |
 |
 |
cUL 508 (E175531) |
 |
 |
 |
 |
 |
 |
 |
Hazardous locations |
 |
 |
 |
cUL 1604 Class 1 Div 2 (E203960) |
 |
 |
 |
 |
 |
 |
 |
Safety of information technology
equipment |
 |
 |
 |
cUL 1950 (E168643) |
 |
 |
 |
 |
 |
 |
 |
Germanischer Lloyd |
 |
 |
 |
Germanischer Lloyd (43 109-02
HH) |
 |
 |
 |
 |
 |
 |
 |
Scope of delivery
and accessories |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Scope of delivery |
 |
 |
 |
device, operating manual |
 |
 |
 |
 |