RPS 120 |
|
|
|
|
|
|
|
|
|
|
Product description |
|
|
|
|
|
|
|
|
|
|
|
Description |
|
|
|
24 V DC DIN rail power
supply unit |
|
|
|
|
|
|
|
Type |
|
|
|
RPS 120 |
|
|
|
|
|
|
|
Order No. |
|
|
|
943 662-011 |
|
|
|
|
|
|
|
More Interfaces |
|
|
|
|
|
|
|
|
|
|
|
Voltage input |
|
|
|
1 terminal block,
3-pin |
|
|
|
|
|
|
|
Voltage output |
|
|
|
1 terminal block,
4-pin |
|
|
|
|
|
|
|
Power requirements |
|
|
|
|
|
|
|
|
|
|
|
Operating voltage |
|
|
|
Selector switch 230
V/115 V |
|
|
|
|
|
|
|
Input data |
|
|
|
|
|
|
|
|
|
|
|
230 V |
|
|
|
176 to 264 V AC; 47
to 63 Hz or 210 to 375 V DC |
|
|
|
|
|
|
|
115 V |
|
|
|
85 to 132 V AC; 47
to 63 Hz |
|
|
|
|
|
|
|
Current consumption |
|
|
|
|
|
|
|
|
|
|
|
230 V |
|
|
|
Max. 1,4 A at 264
V AC |
|
|
|
|
|
|
|
115 V |
|
|
|
Max. 2,6 A at 264
V AC |
|
|
|
|
|
|
|
Activation current |
|
|
|
< 15 A at 264 V AC
and cold start |
|
|
|
|
|
|
|
Output data |
|
|
|
|
|
|
|
|
|
|
|
Output voltage |
|
|
|
24 V DC (-1%, +5%) |
|
|
|
|
|
|
|
Output current |
|
|
|
|
|
|
|
|
|
|
|
230 V |
|
|
|
5 A at 176 - 264V
AC 5 A at 210 - 375 V DC |
|
|
|
|
|
|
|
115 V |
|
|
|
5 A at 85 - 132 V
AC |
|
|
|
|
|
|
|
Service |
|
|
|
|
|
|
|
|
|
|
|
Diagnostics |
|
|
|
LED (power, goes out
at U out < 12 V) |
|
|
|
|
|
|
|
Redundancy |
|
|
|
|
|
|
|
|
|
|
|
Redundancy functions |
|
|
|
Power supply units
can be connected in parallel |
|
|
|
|
|
|
|
Ambient conditions |
|
|
|
|
|
|
|
|
|
|
|
Operating temperature |
|
|
|
-10 °C to +70 °C (from
60 °C derating) |
|
|
|
|
|
|
|
Storage/transport temperature |
|
|
|
-25 °C to +85 °C |
|
|
|
|
|
|
|
Relative humidity (non-condensing) |
|
|
|
10 to 90 % |
|
|
|
|
|
|
|
MTBF |
|
|
|
59.3 years; Siemensnorm
SN 29500 : 40 °C |
|
|
|
|
|
|
|
Mechanical construction |
|
|
|
|
|
|
|
|
|
|
|
Dimensions (W x H x D) |
|
|
|
65 mm x 125 mm x 103
mm |
|
|
|
|
|
|
|
Mounting |
|
|
|
DIN Rail 35 mm |
|
|
|
|
|
|
|
Weight |
|
|
|
620 g |
|
|
|
|
|
|
|
Protection class |
|
|
|
IP 20 |
|
|
|
|
|
|
|
EMC interference
immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 50082-1 |
|
|
|
EN 50082-1 |
|
|
|
|
|
|
|
EN 50082-2 |
|
|
|
EN 50082-2 |
|
|
|
|
|
|
|
EMC emitted
immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 50081-1 |
|
|
|
EN 50081-1 |
|
|
|
|
|
|
|
EN 50081-2 |
|
|
|
EN 50081-2 |
|
|
|
|
|
|
|
Approvals |
|
|
|
|
|
|
|
|
|
|
|
Safety of industrial control
equipment |
|
|
|
cUL 508 (E 198865) |
|
|
|
|
|
|
|
Safety of information technology
equipment |
|
|
|
cUL 60950 (E 137006) |
|
|
|
|
|
|
|
Scope of delivery
and accessories |
|
|
|
|
|
|
|
|
|
|
|
Scope of delivery |
|
|
|
Rail power supply,
Description and operating manual |
|
|
|
|