 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
 |
 |
 |
M-SFP-LH+/LC |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Product description |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Description |
 |
 |
 |
SFP Fiberoptic Gigabit
Ethernet Transceiver for: MICE media modules, MM4-4TX/SFP and MM4-2TX/SFP,
OpenRail RS30-Switches, MACH 4002 48+4G, SmartLION and GigaLION. |
 |
 |
 |
 |
 |
 |
 |
Port type and quantity |
 |
 |
 |
1 x 1000BASE-LX with
LC connector |
 |
 |
 |
 |
 |
 |
 |
Type |
 |
 |
 |
M-SFP-LH+/LC |
 |
 |
 |
 |
 |
 |
 |
Order No. |
 |
 |
 |
943 049-001 |
 |
 |
 |
 |
 |
 |
 |
Network size
- length of cable |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Single mode fiber (LH) 9/125
µm (long haul transceiver) |
 |
 |
 |
60 - 120 km
15 - 32 dB link budget at 1550 nm
A = 0.25 dB/km, 3 dB reserve, D = 19 ps/(nm x km) |
 |
 |
 |
 |
 |
 |
 |
Power requirements |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating voltage |
 |
 |
 |
power supply via the
media module |
 |
 |
 |
 |
 |
 |
 |
Power consumption |
 |
 |
 |
1 W |
 |
 |
 |
 |
 |
 |
 |
Service |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Diagnostics |
 |
 |
 |
optical input and
output power, transceiver temperature |
 |
 |
 |
 |
 |
 |
 |
Ambient conditions |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating temperature |
 |
 |
 |
0 ºC to +60 ºC |
 |
 |
 |
 |
 |
 |
 |
Storage/transport temperature |
 |
 |
 |
-25 ºC to +70 ºC |
 |
 |
 |
 |
 |
 |
 |
Relative humidity (non-condensing) |
 |
 |
 |
10% to 95% |
 |
 |
 |
 |
 |
 |
 |
Mechanical construction |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Dimensions (W x H x D) |
 |
 |
 |
38 mm x 134 mm x 118
mm |
 |
 |
 |
 |
 |
 |
 |
Mounting |
 |
 |
 |
DIN Rail 35 mm |
 |
 |
 |
 |
 |
 |
 |
Weight |
 |
 |
 |
40 g |
 |
 |
 |
 |
 |
 |
 |
Protection class |
 |
 |
 |
IP 20 |
 |
 |
 |
 |
 |
 |
 |
Mechanical stability |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
IEC 60068-2-27 shock |
 |
 |
 |
15 g, 11 ms duration,
18 shocks |
 |
 |
 |
 |
 |
 |
 |
IEC 60068-2-6 vibration |
 |
 |
 |
1 mm, 2 Hz - 13.2
Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz,
10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
 |
 |
 |
 |
 |
 |
 |
EMC interference
immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-2 electrostatic
discharge (ESD) |
 |
 |
 |
6 kV contact discharge,
8 kV air discharge |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-3 electromagnetic
field |
 |
 |
 |
10 V/m (80 - 1000
MHz) |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-4 fast transients
(burst) |
 |
 |
 |
2 kV power line, 1
kV data line |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-5 surge voltage |
 |
 |
 |
power line: 2 kV (line/earth),
1 kV (line/line), 1kV data line |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-6 conducted immunity |
 |
 |
 |
3 V (10 kHz - 150
kHz), 10 V (150 kHz - 80 MHz) |
 |
 |
 |
 |
 |
 |
 |
EMC emitted
immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
FCC CFR47 Part 15 |
 |
 |
 |
FCC CFR47 Part 15
Class A |
 |
 |
 |
 |
 |
 |
 |
EN 55022 |
 |
 |
 |
EN 55022 Class A |
 |
 |
 |
 |
 |
 |
 |
Approvals |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Safety of industrial control
equipment |
 |
 |
 |
cUL 508 (E175531) |
 |
 |
 |
 |
 |
 |
 |
Hazardous locations |
 |
 |
 |
cUL 1604 Class 1 Div
2 (E203960) |
 |
 |
 |
 |
 |
 |
 |
Safety of information technology
equipment |
 |
 |
 |
cUL 60950 (E168643) |
 |
 |
 |
 |
 |
 |
 |
Germanischer Lloyd |
 |
 |
 |
Germanischer Lloyd
(43 109-02 HH) |
 |
 |
 |
 |
 |
 |
 |
Scope of delivery
and accessories |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Scope of delivery |
 |
 |
 |
SFP module |
 |
 |
 |
 |
 |
 |
 |
Accessories to order separately |
 |
 |
 |
media module MM4-4TX/SFP;
order no: 943 010-001 |
 |
 |
 |
 |