OZDV 2451 G |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Product description |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Description |
 |
 |
 |
interface converter
electrical/optical for V.24; power supply through data signal; for
quartz glass FO; for plugging onto the Sub-D socket provided on the
terminal or mounting onto a DIN rail (with DIN rail adapter accessories) |
 |
 |
 |
 |
 |
 |
 |
Port type and quantity |
 |
 |
 |
1 electrical port:
25-pin Sub-D connector, male; 1 optical port: 2 sockets BFOC 2.5 (STR) |
 |
 |
 |
 |
 |
 |
 |
Setting possibilities |
 |
 |
 |
DTE- or DCE operating
mode external voltage supply via pin 11 or internally from the data
signal shield ground galvanically connected or not connected to signal
ground |
 |
 |
 |
 |
 |
 |
 |
Type |
 |
 |
 |
OZDV 2451 G |
 |
 |
 |
 |
 |
 |
 |
Order No. |
 |
 |
 |
943 299-021 |
 |
 |
 |
 |
 |
 |
 |
Electrical interface |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Signal type |
 |
 |
 |
V.24 (RS 232 D) interface
level |
 |
 |
 |
 |
 |
 |
 |
Bit rate |
 |
 |
 |
DC to 20 kbit/s (DC
coupling) |
 |
 |
 |
 |
 |
 |
 |
Bit error frequency |
 |
 |
 |
< 10-9 |
 |
 |
 |
 |
 |
 |
 |
Terminal assignment data |
 |
 |
 |
pin 1: PGND; pin 7:
GND; pin 11: Vcc; pin 4+5 and pin 6+8+20 bridged DTE operation: pin
2 TxD, pin 3 RxD DCE operation: pin 2 RxD, pin 3 TxD |
 |
 |
 |
 |
 |
 |
 |
Optical interface |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Wavelength |
 |
 |
 |
860 nm |
 |
 |
 |
 |
 |
 |
 |
More Interfaces |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Power supply |
 |
 |
 |
from the data signal
(electrical interface) or 25-pin Sub-D connector (pin 11) |
 |
 |
 |
 |
 |
 |
 |
Network size
- length of cable |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Multimode fiber (MM) 50/125
µm |
 |
 |
 |
0 - 1500 m 7.5 dB
link budget, A = 3.0 dB/km, 3 dB reserve |
 |
 |
 |
 |
 |
 |
 |
Multimode fiber (MM) 62.5/125
µm |
 |
 |
 |
0 - 2000 m 10 dB link
budget, A = 3.5 dB/km, 3 dB reserve |
 |
 |
 |
 |
 |
 |
 |
Power requirements |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating voltage |
 |
 |
 |
no external power
supply required; with supply via pin 11: -20 V ... -5 V or +5 V ...
+20 V |
 |
 |
 |
 |
 |
 |
 |
Current consumption |
 |
 |
 |
3.3 mA (max. 3.8 mA)
via data signal |
 |
 |
 |
 |
 |
 |
 |
Power consumption |
 |
 |
 |
20 mW at 4.5 V |
 |
 |
 |
 |
 |
 |
 |
Ambient conditions |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating temperature |
 |
 |
 |
0 °C to +50 °C |
 |
 |
 |
 |
 |
 |
 |
Storage/transport temperature |
 |
 |
 |
-20 °C to +70 °C |
 |
 |
 |
 |
 |
 |
 |
Relative humidity |
 |
 |
 |
10% to 90% |
 |
 |
 |
 |
 |
 |
 |
Mechanical construction |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Dimensions (W x H x D) |
 |
 |
 |
56.5 x 18 x 76 mm |
 |
 |
 |
 |
 |
 |
 |
Mounting |
 |
 |
 |
plugging onto the
terminal unit |
 |
 |
 |
 |
 |
 |
 |
Weight |
 |
 |
 |
110 g |
 |
 |
 |
 |
 |
 |
 |
Protection class |
 |
 |
 |
IP 40 |
 |
 |
 |
 |
 |
 |
 |
Housing material |
 |
 |
 |
die-cast zink |
 |
 |
 |
 |
 |
 |
 |
EMC interference
immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-2 electrostatic
discharge (ESD) |
 |
 |
 |
contact discharge:
4 kV, air discharge: 8 kV |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-3 electromagnetic
field |
 |
 |
 |
10 V/m (80 - 1000
MHz) |
 |
 |
 |
 |
 |
 |
 |
EMC emitted
immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
EN 55022 |
 |
 |
 |
EN 55022 limit class
B |
 |
 |
 |
 |
 |
 |
 |
Approvals |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Issued approvals |
 |
 |
 |
C-Tick |
 |
 |
 |
 |
 |
 |
 |
Scope of delivery
and accessories |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Scope of delivery |
 |
 |
 |
device, operating
instructions |
 |
 |
 |
 |
 |
 |
 |
Accessories to order separately |
 |
 |
 |
DIN rail adapter OZDV
HA |
 |
 |
 |
 |