OZDV 2451 P |
|
|
|
|
|
|
|
|
|
|
Product description |
|
|
|
|
|
|
|
|
|
|
|
Description |
|
|
|
interface converter
electrical/optical for V.24; power supply through data signal; for
plastic FO; for plugging onto the Sub-D socket provided on the terminal
or mounting onto a DIN rail (with DIN rail adapter accessories) |
|
|
|
|
|
|
|
Port type and quantity |
|
|
|
1 electrical port:
25-pin Sub-D connector, male; 1 optical port: 2 sockets BFOC 2.5 (STR) |
|
|
|
|
|
|
|
Setting possibilities |
|
|
|
DTE- or DCE operating
mode external voltage supply via pin 11 or internally from the data
signal shield ground galvanically connected or not connected to signal
ground |
|
|
|
|
|
|
|
Type |
|
|
|
OZDV 2451 P |
|
|
|
|
|
|
|
Order No. |
|
|
|
943 316-021 |
|
|
|
|
|
|
|
Electrical interface |
|
|
|
|
|
|
|
|
|
|
|
Signal type |
|
|
|
V.24 (RS 232 D) interface
level |
|
|
|
|
|
|
|
Bit rate |
|
|
|
DC to 20 kbit/s (DC
coupling) |
|
|
|
|
|
|
|
Bit error frequency |
|
|
|
< 10-9 |
|
|
|
|
|
|
|
Terminal assignment data |
|
|
|
pin 1: PGND; pin 7:
GND; pin 11: Vcc; pin 4+5 and pin 6+8+20 bridged DTE operation: pin
2 TxD, pin 3 RxD DCE operation: pin 2 RxD, pin 3 TxD |
|
|
|
|
|
|
|
Optical interface |
|
|
|
|
|
|
|
|
|
|
|
Wavelength |
|
|
|
665 nm |
|
|
|
|
|
|
|
More Interfaces |
|
|
|
|
|
|
|
|
|
|
|
Power supply |
|
|
|
from the data signal
(electrical interface) or 25-pin Sub-D connector (pin 11) |
|
|
|
|
|
|
|
Network size
- length of cable |
|
|
|
|
|
|
|
|
|
|
|
Multimode fiber POF (MM) 980/1000
µm |
|
|
|
0 - 60 m 17 dB link
budget, A = 0.25 dB/m, 2 dB reserve |
|
|
|
|
|
|
|
Power requirements |
|
|
|
|
|
|
|
|
|
|
|
Operating voltage |
|
|
|
no external power
supply required; with supply via pin 11: -20 V ... -5 V or +5 V ...
+20 V |
|
|
|
|
|
|
|
Current consumption |
|
|
|
3.3 mA (max. 3.8 mA)
via data signal |
|
|
|
|
|
|
|
Power consumption |
|
|
|
20 mW at 4.5 V |
|
|
|
|
|
|
|
Ambient conditions |
|
|
|
|
|
|
|
|
|
|
|
Operating temperature |
|
|
|
0 °C to +50 °C |
|
|
|
|
|
|
|
Storage/transport temperature |
|
|
|
-20 °C to +70 °C |
|
|
|
|
|
|
|
Relative humidity |
|
|
|
10% to 90% |
|
|
|
|
|
|
|
Mechanical construction |
|
|
|
|
|
|
|
|
|
|
|
Dimensions (W x H x D) |
|
|
|
56.5 x 18 x 76 mm |
|
|
|
|
|
|
|
Mounting |
|
|
|
plugging onto the
terminal unit |
|
|
|
|
|
|
|
Weight |
|
|
|
110 g |
|
|
|
|
|
|
|
Protection class |
|
|
|
IP 40 |
|
|
|
|
|
|
|
Housing material |
|
|
|
die-cast zink |
|
|
|
|
|
|
|
EMC interference
immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 61000-4-2 electrostatic
discharge (ESD) |
|
|
|
contact discharge:
4 kV, air discharge: 8 kV |
|
|
|
|
|
|
|
EN 61000-4-3 electromagnetic
field |
|
|
|
10 V/m (80 - 1000
MHz) |
|
|
|
|
|
|
|
EMC emitted
immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 55022 |
|
|
|
EN 55022 limit class
B |
|
|
|
|
|
|
|
Approvals |
|
|
|
|
|
|
|
|
|
|
|
Issued approvals |
|
|
|
C-Tick |
|
|
|
|
|
|
|
Scope of delivery
and accessories |
|
|
|
|
|
|
|
|
|
|
|
Scope of delivery |
|
|
|
device, operating
instructions, 2 BFOC ST optical plugs |
|
|
|
|
|
|
|
Accessories to order separately |
|
|
|
DIN rail adapter OZDV
HA |
|
|
|
|