Product description
Description interface converter electrical/optical for V.24; for plastic FO; for plugging onto the Sub-D socket provided on the terminal or mounting onto a DIN rail (with DIN rail adapter accessories)
Port type and quantity 1 electrical port: 25-pin Sub-D connector, male; 1 optical port: 2 sockets BFOC 2.5 (STR)
Setting possibilities DTE- or DCE operating mode voltage supply internally via pin 11/pin 18 Sub-D socket or externally via low voltage socket shield ground galvanically connected or not connected to signal ground
Type OZDV 2471 P
Order No. 943 340-021
Electrical interface
Signal type V.24 (RS 232 D) interface level
Bit rate DC to 115 kbit/s (DC coupling)
Bit error frequency < 10-9
Terminal assignment data pin 1: PGND; pin 7: GND; pin 11: Vcc; pin 4+5 and pin 6+8+20 bridged DTE operation: pin 2 TxD, pin 3 RxD DCE operation: pin 2 RxD, pin 3 TxD
Optical interface
Wavelength 665 nm
More Interfaces
Power supply 4-pin low voltage plug, M8 shape according to IEC 947-5-2 or 25-pin Sub-D connector (pin 11/pin 18)
Network size - length of cable
Multimode fiber HCS (MM) 200/230 µm 0 - 2100 m 20 dB link budget, A = 8.0 dB/km, 3 dB reserve
Multimode fiber POF (MM) 980/1000 µm 0 - 100 m 29 dB link budget, A = 0.25 dB/m, 2 dB reserve
Power requirements
Operating voltage +5 VDC via PSW 5-24 plug-in power supply or + 5 VDC +-5% external supply or +8 ... +15 VDC external supply
Current consumption 90 mA (max. 120 mA)
Power consumption 0.6 W/1.8 W
Ambient conditions
Operating temperature -20 ºC to +50 ºC
Storage/transport temperature -20 ºC to +70 ºC
Relative humidity 10% to 90%
Mechanical construction
Dimensions (W x H x D) 56.5 x 18 x 76 mm
Mounting plugging onto the terminal unit
Weight 110 g
Protection class IP 40
Housing material die-cast zink
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) contact discharge: 4 kV, air discharge: 8 kV
EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst) 2 kV (plug-in power supply 220 V side)
EN 61000-4-5 surge voltage power line: 1 kV (line/line), 2 kV (line/earth) (plug-in power supply 220 V side)
EMC emitted immunity
EN 55022 EN 55022 limit class B
Approvals
Issued approvals C-Tick
Scope of delivery and accessories
Scope of delivery device, operating instructions, 2 BFOC optical plugs
Accessories to order separately plug-in power supply PSW 5-24 DIN rail adapter OZDV HA