Industrial Networking
FiberINTERFACES
Digital
Field Bus
Universal RS 485 Fiberoptic Repeaters
PROFIBUS Fiberoptic Repeaters
Genius Bus Fiberoptic Repeaters
FIP Bus Fiberoptic Repeaters
Modbus Plus Fiberoptic Repeaters
Video
Hybrids modules and OptoQuick components
Accessories
Industrial Ethernet
Hirschmann Networks
         
OZD Genius G12-1300
Product description
Description interface converter electrical/optical for Genius field bus networks; repeater function; for quartz glass FO; approval for Ex-zone 2 (Class 1, Div. 2); long-haul version
Port type and quantity 2 x optical: 4 sockets BFOC 2.5 (STR) 1 x electrical: 4-pin connector with self-locking mechanism
Type OZD Genius G12-1300
Order No. 934 233-021
Electrical interface
Signal type Geniusbus
Bit rate 38.4; 76.8; 153.6 kbit/s
Signal delay time (optional input/output) 800 ns
Input/output signal Geniusbus
Genius cable length: >250 m attenuation at 1 MHz: <8 dB for 150 Ohm cable <5 dB for 100 Ohm cable
Connection capability max. 32 terminal devices
Terminator external
Galvanic isolation shielding in/shielding out: yes; data lines/housing: yes
Optical interface
Wavelength 1310 nm
Launchable optical power in single-mode fiber (SM) 9/125 -19 dBm
Launchable optical power in multi-mode fiber (MM) 50/125 -17 dBm
Launchable optical power in multi-mode fiber (MM) 62.5/125 -17 dBm
Optical input power min. -27 dBm, max. -3 dBm
Cascadibility not limited
More Interfaces
Power supply 5-pin terminal block, screw mounting
Signaling contact 5-pin terminal block, screw mounting
Network size - length of cable
Single mode fiber (SM) 9/125 µm 10000 m 8 dB link budget at 1310 nm; A = 0.5 dB/km, 2 dB reserve
Multimode fiber (MM) 50/125 µm 7000 m 10 dB link budget at 1310 nm; A = 1 dB/km, 3 dB reserve
Multimode fiber (MM) 62.5/125 µm 7000 m 10 dB link budget at 1310 nm; A = 1 dB/km, 3 dB reserve
Power requirements
Operating voltage 24 VDC (19 ... 35 VDC), non-interchangeable, safety extra-low voltage
Current consumption 130 mA
Power consumption 3.1 W
Redundancy
Redundancy functions HIPER-Ring (ring structure), redundant 24 V infeed
Displays
LED red/green (system) monitoring operating voltage and data traffic
LED green/orange (Port 1) differentiated monitoring electrical channel
LED green/orange (Port 2,3) differentiated monitoring optical channels
Ambient conditions
Operating temperature 0 ºC to +55 ºC
Storage/transport temperature -40 ºC to +80 ºC
Relative humidity <95% (non-condensing)
Mechanical construction
Dimensions (W x H x D) 40 x 111 x 73.5 mm
Mounting DIN rail or mounting plate
Weight 500 g
Protection class IP 40
Housing material die-cast zink
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) contact discharge: 4 kV, air discharge: 8 kV, HCP/VCP: 4 kV
EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst) power line 2 kV, data line: 1 kV
EN 61000-4-5 surge voltage power line 0.5 kV (line/line, line/earth), data line: 1 kV
EN 61000-4-6 conducted immunity 10 V (0.15 - 80 MHz)
EMC emitted immunity
EN 55022 EN 55022 limit class A
Approvals
Issued approvals cUL Class 1, Div.2; C-Tick
Scope of delivery and accessories
Scope of delivery device, start-up instructions
Accessories to order separately manual, order no. 933 989-901