OZD 485 G12
PRO |
|
|
|
|
|
|
|
|
|
|
Product description |
|
|
|
|
|
|
|
|
|
|
|
Description |
|
|
|
Interface converter
electrical/optical for RS 485 field bus networks; repeater function;
for quartz glass FO; electrical full duplex or semi-duplex mode |
|
|
|
|
|
|
|
Port type and quantity |
|
|
|
2 x optical: BFOC
2.5 (STR) socket
1 x electrical: 6-pin terminal block |
|
|
|
|
|
|
|
Type |
|
|
|
OZD 485 G12 PRO |
|
|
|
|
|
|
|
Order No. |
|
|
|
943 894-321 |
|
|
|
|
|
|
|
Electrical interface |
|
|
|
|
|
|
|
|
|
|
|
Signal type |
|
|
|
RS 485 |
|
|
|
|
|
|
|
Input resistance |
|
|
|
10 kOhm |
|
|
|
|
|
|
|
Input voltage range |
|
|
|
-7 V ... +12 V |
|
|
|
|
|
|
|
Jitter |
|
|
|
typ. 10 nspp |
|
|
|
|
|
|
|
Distortion of bit duration |
|
|
|
typ. 1 nspp |
|
|
|
|
|
|
|
Bit rate |
|
|
|
0 to 1,5 Mbit/s NRZ |
|
|
|
|
|
|
|
Optical interface |
|
|
|
|
|
|
|
|
|
|
|
Wavelength |
|
|
|
860 nm |
|
|
|
|
|
|
|
Launchable optical power in
multi-mode fiber (MM) 50/125 |
|
|
|
-20 dBm |
|
|
|
|
|
|
|
Launchable optical power in
multi-mode fiber (MM) 62.5/125 |
|
|
|
-16 dBm |
|
|
|
|
|
|
|
Optical input power |
|
|
|
-30 dBm |
|
|
|
|
|
|
|
More Interfaces |
|
|
|
|
|
|
|
|
|
|
|
Power supply |
|
|
|
7-pin terminal block |
|
|
|
|
|
|
|
Signaling contact |
|
|
|
7-pin terminal block |
|
|
|
|
|
|
|
Voltage output |
|
|
|
3-pin terminal block |
|
|
|
|
|
|
|
Network size
- length of cable |
|
|
|
|
|
|
|
|
|
|
|
Multimode fiber (MM) 50/125
µm |
|
|
|
2300 m
10 dB link budget at 860 nm; A = 3 dB/km, 3 dB reserve |
|
|
|
|
|
|
|
Multimode fiber (MM) 62.5/125
µm |
|
|
|
3100 m
14 dB link budget at 860 nm; A = 3,5 dB/km, 3 dB reserve |
|
|
|
|
|
|
|
System delay time |
|
|
|
<1,56 us |
|
|
|
|
|
|
|
Power requirements |
|
|
|
|
|
|
|
|
|
|
|
Operating voltage |
|
|
|
18 ... 32 VDC (typ.
24 VDC) |
|
|
|
|
|
|
|
Current consumption |
|
|
|
140 mA at 24 VDC,
65 mA at 32 VDC |
|
|
|
|
|
|
|
Power consumption |
|
|
|
<3.5 W |
|
|
|
|
|
|
|
Redundancy |
|
|
|
|
|
|
|
|
|
|
|
Redundancy functions |
|
|
|
redundant ring, redundant
power supply |
|
|
|
|
|
|
|
Displays |
|
|
|
|
|
|
|
|
|
|
|
LEDs |
|
|
|
system (operating
status, signaling contact); supply voltage; redundancy mode; input
signal/input power/receiving data |
|
|
|
|
|
|
|
Ambient conditions |
|
|
|
|
|
|
|
|
|
|
|
Operating temperature |
|
|
|
-25 ºC to +70 ºC |
|
|
|
|
|
|
|
Storage/transport temperature |
|
|
|
-25 ºC to +80 ºC |
|
|
|
|
|
|
|
Relative humidity |
|
|
|
<95% (non-condensing) |
|
|
|
|
|
|
|
Mechanical construction |
|
|
|
|
|
|
|
|
|
|
|
Dimensions (W x H x D) |
|
|
|
35x156x119 |
|
|
|
|
|
|
|
Mounting |
|
|
|
DIN rail |
|
|
|
|
|
|
|
Weight |
|
|
|
195 g |
|
|
|
|
|
|
|
Protection class |
|
|
|
IP 20 |
|
|
|
|
|
|
|
Housing material |
|
|
|
plastics |
|
|
|
|
|
|
|
EMC interference
immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 61000-4-2 electrostatic
discharge (ESD) |
|
|
|
contact discharge:
4 kV, air discharge: 8 kV |
|
|
|
|
|
|
|
EN 61000-4-3 electromagnetic
field |
|
|
|
10 V/m (80 - 1000
MHz and 1400 - 2000 MHz) |
|
|
|
|
|
|
|
EN 61000-4-4 fast transients
(burst) |
|
|
|
power line 2 kV, data
line: 1 kV |
|
|
|
|
|
|
|
EN 61000-4-5 surge voltage |
|
|
|
power line 1 kV (line/line,
line/earth), data line: 1 kV |
|
|
|
|
|
|
|
EN 61000-4-6 conducted immunity |
|
|
|
10 V (0.15 - 80 MHz) |
|
|
|
|
|
|
|
EMC emitted
immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 55022 |
|
|
|
EN 55022 limit class
A |
|
|
|
|
|
|
|
Approvals |
|
|
|
|
|
|
|
|
|
|
|
planned approvals |
|
|
|
cUL508, cUL1604 Class1,
Div. 2, Groups A,B,C and D. According to ATEX 100a: Ex II 3 G |
|
|
|
|
|
|
|
Scope of delivery
and accessories |
|
|
|
|
|
|
|
|
|
|
|
Scope of delivery |
|
|
|
device, start-up instructions |
|
|
|
|
|
|
|
Accessories to order separately |
|
|
|
manual, order no.
039 516-001 |
|
|
|
|