Industrial Networking
FiberINTERFACES
Digital
Field Bus
Video
Hybrids modules and OptoQuick components
Digital Hybrids
Audio Hybrids
OptoQuick Components
Accessories
Industrial Ethernet
Hirschmann Networks
 
OEAH 200
Product description
Description optical audio receiver hybrid; PCB mounting
Port type and quantity 1 electrical port: 1 pin
Type OEAH 200
Order No. 943 044-001
Electrical interface
Output voltage 0 dBm = 0.775 Veff (no load)
Admissible load resistance at the output >=600 Ohm
Linear distortion (30 Hz to 20 kHz) <=0.5 dB at 0 °C to +50 °C / <=0.8 dB at -40 °C to +80 °C
Distorsion factor (at 0 dBm/1kHz) <=0.1% at 0 °C to +50 °C / <=0.15% at -40 °C to +80 °C
Unweighted signal-to-noise-ratio (relative 0 dBm) >73 dB at 0 °C to +50 °C / >68 dB at -40 °C to +80 °C
Bandwidth (-3 dB) 10 Hz to 30 kHz at 0 °C to +50 °C / 15 Hz to 30 kHz at -40 °C to +80 °C
Optical interface
Optical input power >2.0 µWpp, -27 dBm at 0 °C to +50 °C with OVKD 01-B (SFH 203 P) (accessories)
Network size - length of cable
Multimode fiber POF (MM) 980/1000 µm 88 m 24 dB link budget, A = 0.25 dB/m, 2 dB system reserve with OSAH 200 with OVKD 01-B (LED 013) (accessories) and OVK 01-B (SFH 203 P) (accessories)
Power requirements
Operating voltage +12 VDC +-10%
Current consumption 35 mA
Power consumption 0.4 W
Drawing
 
Ambient conditions
Operating temperature -40 °C to +80 °C
Storage/transport temperature -40 °C to +80 °C
Relative humidity (non-condensing) 10% to 90%
Mechanical construction
Dimensions (W x H x D) see "Drawing"
Mounting on PCB
Weight 15 g
Protection class IP 65
Pin assignment see "Drawing" pin 1: pin diode; pin 2-10: GND; pin 11: output pin 12: gain setting; pin 13-24: VCC
Scope of delivery and accessories
Scope of delivery 1 hybird, 1 operating instructions
Accessories to order separately optical converter OVKD 01-B (SFH 203 P), order no. 936 215-037 scope of delivery: 1 converter housing with integrated and adjusted receiver element, type OVK for platic fiber On request, we will be pleased to supply a data sheet indicating the dimensions and terminal assignment of the converter housing.