OEV 052 BFOC-1300 |
|
|
|
|
|
|
|
|
|
|
Product description |
|
|
|
|
|
|
|
|
|
|
|
Description |
|
|
|
Composite video receiver
7 MHz; can be combined with the transmitter OSVC 01 BFOC-1300 |
|
|
|
|
|
|
|
Port type and quantity |
|
|
|
1 x optical: BFOC
2.5 (STR) socket 1 x electrical: BNC socket |
|
|
|
|
|
|
|
Type |
|
|
|
OEV 052 BFOC-1300 |
|
|
|
|
|
|
|
Order No. |
|
|
|
933 993-021 |
|
|
|
|
|
|
|
Electrical interface |
|
|
|
|
|
|
|
|
|
|
|
Signal type |
|
|
|
composite |
|
|
|
|
|
|
|
Output voltage |
|
|
|
1 Vpp at 75 Ohm |
|
|
|
|
|
|
|
Output resistance |
|
|
|
75 Ohm |
|
|
|
|
|
|
|
Pulse tilt (horiz. and vert.) |
|
|
|
typ. 2% |
|
|
|
|
|
|
|
Differential phase |
|
|
|
typ. 2.5° |
|
|
|
|
|
|
|
Upper limiting frequency (-3
dB) |
|
|
|
7 MHz |
|
|
|
|
|
|
|
Optical interface |
|
|
|
|
|
|
|
|
|
|
|
Wavelength |
|
|
|
1300 nm |
|
|
|
|
|
|
|
Optical input power |
|
|
|
>= 0.8 µWpp, -31 dBm
with S/N > 45 dBw |
|
|
|
|
|
|
|
Laser protection class |
|
|
|
1 according to DIN
EN 60825 |
|
|
|
|
|
|
|
More Interfaces |
|
|
|
|
|
|
|
|
|
|
|
Power supply |
|
|
|
low voltage socket,
device polarity: pin: +Vs/socket: ground |
|
|
|
|
|
|
|
Network size
- length of cable |
|
|
|
|
|
|
|
|
|
|
|
Single mode fiber (SM) 9/125
µm |
|
|
|
10000 m 7 dB link
budget, A = 0,5 dB/km, 2 dB reserve with OSVC 01 BFOC-1300 (26000
m/15 dB at +25 °C) |
|
|
|
|
|
|
|
Power requirements |
|
|
|
|
|
|
|
|
|
|
|
Operating voltage |
|
|
|
12 ... 15 V |
|
|
|
|
|
|
|
Current consumption |
|
|
|
120 mA |
|
|
|
|
|
|
|
Power consumption |
|
|
|
1.8 W |
|
|
|
|
|
|
|
Ambient conditions |
|
|
|
|
|
|
|
|
|
|
|
Operating temperature |
|
|
|
-20 °C to +50 °C |
|
|
|
|
|
|
|
Storage/transport temperature |
|
|
|
-20 °C to +80 °C |
|
|
|
|
|
|
|
Relative humidity (non-condensing) |
|
|
|
10% to 90% |
|
|
|
|
|
|
|
Mechanical construction |
|
|
|
|
|
|
|
|
|
|
|
Mounting |
|
|
|
stand-alone unit |
|
|
|
|
|
|
|
Dimensions (W x H x D) |
|
|
|
100 x 24.1 x 50 mm |
|
|
|
|
|
|
|
Weight |
|
|
|
210 g |
|
|
|
|
|
|
|
Protection class |
|
|
|
IP 40 |
|
|
|
|
|
|
|
EMC interference
immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 61000-4-2 electrostatic
discharge (ESD) |
|
|
|
contact discharge:
4 kV, air discharge: 8 kV |
|
|
|
|
|
|
|
EN 61000-4-3 electromagnetic
field |
|
|
|
10 V/m (80 - 1000
MHz) |
|
|
|
|
|
|
|
EN 61000-4-4 fast transients
(burst) |
|
|
|
power line: 2 kV,
data line: 1 kV |
|
|
|
|
|
|
|
EN 61000-4-5 surge voltage |
|
|
|
power line: 1 kV (line/line) |
|
|
|
|
|
|
|
EMC emitted
immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 55022 |
|
|
|
EN 55022 limit class
B |
|
|
|
|
|
|
|
Scope of delivery
and accessories |
|
|
|
|
|
|
|
|
|
|
|
Scope of delivery |
|
|
|
ready-to-connect receiver,
operating instructions |
|
|
|
|
|
|
|
Accessories to order separately |
|
|
|
plug-in power supply
SNT 012 |
|
|
|
|
|
|
|
Notes |
|
|
|
|
|
|
|
|
|
|
|
Picture signal |
|
|
|
To ensure correct
operation, the controller requires a degree of whiteness of 0.5% in
the picture signal. |
|
|
|
|