Product description
Description Composite video receiver 50 MHz; can be combinied with the transmitters OSV 052(-E) BFOC, OSVC 01 BFOC, OSVR 80M2-E BFOC, OSVR 150M-PCI64 ...
Port type and quantity 1 x optical: BFOC 2.5 (STR) socket 1 x electrical: BNC socket
Type ORVC G1 BFOC
Order No. 943 688-221
Electrical interface
Signal type composite
Output voltage 1 Vpp at 75 Ohm
Output resistance 75 Ohm
Pulse tilt (horiz. and vert.) typ. 1%
Upper limiting frequency (-3 dB) 50 MHz
Optical interface
Wavelength 860 nm
Optical input power >= 3 µWpp, -25 dBm with S/N > 45 dBw
Laser protection class 1 according to DIN EN 60825
More Interfaces
Power supply 5-pin terminal block, screw mounting
Signaling contact 5-pin terminal block, screw mounting
Network size - length of cable
Multimode fiber (MM) 50/125 µm 1300 m 7 dB link budget, A = 3 dB/km, 3 dB reserve with OSV 052 BFOC, OSV 052-E BFOC, OSVR 80M2-E BFOC 1200 m 6.5 dB link budget, A = 3 dB/km, 3 dB reserve with OSVC 01 BFOC 1000 m 6 dB link budget, A = 3 dB/km, 3 dB reserve with OSVR 150M-PCI64 ...
Multimode fiber (MM) 62.5/125 µm 1700 m 9 dB link budget, A = 3.5 dB/km, 3 dB reserve with OSV 052 BFOC, OSV 052-E BFOC, OSVR 80M2-E BFOC 1400 m 8 dB link budget, A = 3.5 dB/km, 3 dB reserve with OSVC 01 BFOC
Power requirements
Operating voltage 24 VDC (15 ... 26.4 VDC)
Current consumption max. 200 mA
Power consumption 5.3 W
Ambient conditions
Operating temperature 0 °C to +50 °C
Storage/transport temperature -20 °C to +70 °C
Relative humidity (non-condensing) < 95%
Mechanical construction
Mounting Robust metal housing for mounting onto a DIN rail or a mounting plate
Dimensions (W x H x D) 40 x 140 x 92 mm
Weight 500 g
Protection class IP 40
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) contact discharge: 4 kV, air discharge: 8 kV
EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst) power line: 2 kV, data line: 1 kV
EN 61000-4-5 surge voltage power line: 1 kV (line/line)
EMC emitted immunity
EN 55022 EN 55022 limit class B
Scope of delivery and accessories
Scope of delivery ready-to-connect receiver, very-low voltage plug, operating instructions
Accessories to order separately DIN rail power supply RPS 30