ORVC G1 BFOC |
|
|
|
|
|
|
|
|
|
|
Product description |
|
|
|
|
|
|
|
|
|
|
|
Description |
|
|
|
Composite video receiver 50 MHz;
can be combinied with the transmitters
OSV 052(-E) BFOC, OSVC 01 BFOC, OSVR 80M2-E BFOC, OSVR 150M-PCI64 ... |
|
|
|
|
|
|
|
Port type and quantity |
|
|
|
1 x optical: BFOC 2.5 (STR) socket
1 x electrical: BNC socket |
|
|
|
|
|
|
|
Type |
|
|
|
ORVC G1 BFOC |
|
|
|
|
|
|
|
Order No. |
|
|
|
943 688-221 |
|
|
|
|
|
|
|
Electrical interface |
|
|
|
|
|
|
|
|
|
|
|
Signal type |
|
|
|
composite |
|
|
|
|
|
|
|
Output voltage |
|
|
|
1 Vpp at 75 Ohm |
|
|
|
|
|
|
|
Output resistance |
|
|
|
75 Ohm |
|
|
|
|
|
|
|
Pulse tilt (horiz. and vert.) |
|
|
|
typ. 1% |
|
|
|
|
|
|
|
Upper limiting frequency (-3 dB) |
|
|
|
50 MHz |
|
|
|
|
|
|
|
Optical interface |
|
|
|
|
|
|
|
|
|
|
|
Wavelength |
|
|
|
860 nm |
|
|
|
|
|
|
|
Optical input power |
|
|
|
>= 3 µWpp, -25 dBm with S/N > 45 dBw |
|
|
|
|
|
|
|
Laser protection class |
|
|
|
1 according to DIN EN 60825 |
|
|
|
|
|
|
|
More Interfaces |
|
|
|
|
|
|
|
|
|
|
|
Power supply |
|
|
|
5-pin terminal block, screw mounting |
|
|
|
|
|
|
|
Signaling contact |
|
|
|
5-pin terminal block, screw mounting |
|
|
|
|
|
|
|
Network size - length of cable |
|
|
|
|
|
|
|
|
|
|
|
Multimode fiber (MM) 50/125 µm |
|
|
|
1300 m
7 dB link budget, A = 3 dB/km, 3 dB reserve with OSV 052 BFOC, OSV 052-E BFOC,
OSVR 80M2-E BFOC
1200 m
6.5 dB link budget, A = 3 dB/km, 3 dB reserve with OSVC 01 BFOC
1000 m
6 dB link budget, A = 3 dB/km, 3 dB reserve with OSVR 150M-PCI64 ... |
|
|
|
|
|
|
|
Multimode fiber (MM) 62.5/125 µm |
|
|
|
1700 m
9 dB link budget, A = 3.5 dB/km, 3 dB reserve with OSV 052 BFOC, OSV 052-E BFOC,
OSVR 80M2-E BFOC
1400 m
8 dB link budget, A = 3.5 dB/km, 3 dB reserve with OSVC 01 BFOC |
|
|
|
|
|
|
|
Power requirements |
|
|
|
|
|
|
|
|
|
|
|
Operating voltage |
|
|
|
24 VDC (15 ... 26.4 VDC) |
|
|
|
|
|
|
|
Current consumption |
|
|
|
max. 200 mA |
|
|
|
|
|
|
|
Power consumption |
|
|
|
5.3 W |
|
|
|
|
|
|
|
Ambient conditions |
|
|
|
|
|
|
|
|
|
|
|
Operating temperature |
|
|
|
0 °C to +50 °C |
|
|
|
|
|
|
|
Storage/transport temperature |
|
|
|
-20 °C to +70 °C |
|
|
|
|
|
|
|
Relative humidity (non-condensing) |
|
|
|
< 95% |
|
|
|
|
|
|
|
Mechanical construction |
|
|
|
|
|
|
|
|
|
|
|
Mounting |
|
|
|
Robust metal housing for mounting onto a DIN rail or a mounting plate |
|
|
|
|
|
|
|
Dimensions (W x H x D) |
|
|
|
40 x 140 x 92 mm |
|
|
|
|
|
|
|
Weight |
|
|
|
500 g |
|
|
|
|
|
|
|
Protection class |
|
|
|
IP 40 |
|
|
|
|
|
|
|
EMC interference immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 61000-4-2 electrostatic discharge (ESD) |
|
|
|
contact discharge: 4 kV, air discharge: 8 kV |
|
|
|
|
|
|
|
EN 61000-4-3 electromagnetic field |
|
|
|
10 V/m (80 - 1000 MHz) |
|
|
|
|
|
|
|
EN 61000-4-4 fast transients (burst) |
|
|
|
power line: 2 kV, data line: 1 kV |
|
|
|
|
|
|
|
EN 61000-4-5 surge voltage |
|
|
|
power line: 1 kV (line/line) |
|
|
|
|
|
|
|
EMC emitted immunity |
|
|
|
|
|
|
|
|
|
|
|
EN 55022 |
|
|
|
EN 55022 limit class B |
|
|
|
|
|
|
|
Scope of delivery and accessories |
|
|
|
|
|
|
|
|
|
|
|
Scope of delivery |
|
|
|
ready-to-connect receiver, very-low voltage plug, operating instructions |
|
|
|
|
|
|
|
Accessories to order separately |
|
|
|
DIN rail power supply RPS 30 |
|
|
|
|