OEVR 150M Sync FSMA
Product description
Description RGB video receiver 150 MHz;
can be combinied with the transmitters
OSVR 150M-PCI64 ..., OSVR 80M2-E ..., OSVR 150M Sync ..., ODR 150M 3 FSMA
Port type and quantity 3 x optical: FSMA sockets
1 x electrical: HD-Sub 15-pin, according to DIN 41652
Type OEVR 150M Sync FSMA
Order No. 934 016-501
Electrical interface
Signal type RGB, VGA
Output voltage 1 Vpp at 75 Ohm with Sync-in-G operating mode
0.7 Vpp at 75 Ohm with VGA operating mode
Output resistance 75 Ohm
Pulse tilt (horiz. and vert.) 5%
Differential amplification 8%
Upper limiting frequency (-3 dB) 150 MHz (at fiber lengths <400 m)
Resolution VESA standard: > 1280 x 1024
visual: > 1600 x 1200
Optical interface
Wavelength 860 nm
Optical input power >= 3 µWpp, -25 dBm with S/N > 46 dBw
More Interfaces
Power supply 4-pin low voltage plug, M8 shape according to IEC 947-5-2
Network size - length of cable
Multimode fiber (MM) 50/125 µm 1000 m
6 dB link budget, A = 3.0 dB/km, 3 dB reserve
with OSVR 150M ..., OSVR 150M-PCI64 ..., ODR 150M3 FSMA
400 m
4.2 dB link budget, A = 3.0 dB/km, 3 dB reserve
with OSVR 80M2-E FSMA
Multimode fiber (MM) 62.5/125 µm 1400 m
8 dB link budget, A = 3.5 dB/km, 3 dB reserve
with OSVR 150M ..., OSVR 150M-PCI64 ..., ODR 150M3 FSMA
1100 m
7 dB link budget, A = 3.5 dB/km, 3 dB reserve
with OSVR 80M2-E FSMA...
Power requirements
Operating voltage 5 VDC, ripple <50 mVpp
Power consumption 6.5 W
Current consumption 1.3 A
Ambient conditions
Operating temperature 0 ºC to +50 ºC
Storage/transport temperature -20 ºC to +80 ºC
Relative humidity (non-condensing) 10% to 90%
Mechanical construction
Mounting stand-alone unit in an aluminium section housing
Dimensions (W x H x D) 129 x 34.9 x 130.7 mm
Weight 365 g
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) contact discharge: 4 kV, air discharge: 8 kV
EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst) power line: 2 kV
EN 61000-4-5 surge voltage power line: 1 kV (line/line)
EMC emitted immunity
EN 55022 EN 55022 limit class B
Scope of delivery and accessories
Scope of delivery ready-to-connect receiver, plug-in power supply PSW 5-24, operating instructions