Industrial Networking
FiberINTERFACES
Digital
Field Bus
Video
Composite Video Transmitters/Receivers
RGB Video Transmitters/Receivers - High-Resolution
Hybrids modules and OptoQuick components
Accessories
Industrial Ethernet
Hirschmann Networks
         
OSVR 150M BFOC
Product description
Description RGB video transmitter 150 MHz; can be combined with the receiver OEVR 150M Sync BFOC
Port type and quantity 2 x electrical: HD-Sub 15-pin, according to DIN 41652 3 x optical: BFOC 2.5 (STR) sockets
Type OSVR 150M BFOC
Order No. 943 823-021
Electrical interface
Signal type VGA (external synchronisation) or RGB (sync-in-green); switchable
Input voltage 700 mVpp with VGA operating mode 1 Vpp with Sync-in-G operating mode
Input resistance 75 Ohm / 10 kOhm switchable for all inputs
Output voltage like input signal
Differential amplification 8 %
Upper limiting frequency (-3 dB) 150 MHz (at fiber lengths <400 m)
Resolution VESA standard: > 1280 x 1024 visual: > 1600 x 1200
Optical interface
Wavelength 860nm
Launchable optical power in multi-mode fiber (MM) 50/125 >12 µWpp, -19 dBm
Launchable optical power in multi-mode fiber (MM) 62.5/125 >20 µWpp, -17 dBm
Laser protection class 1 according to EN 60825
More Interfaces
Power supply 4-pin low voltage plug, M8 shape according to IEC 947-5-2
Network size - length of cable
Multimode fiber (MM) 50/125 µm 1000 m 6 dB link budget, A = 3.0 dB/km, 3 dB reserve
Multimode fiber (MM) 62.5/125 µm 1400 m 8 dB link budget, A = 3.5 dB/km, 3 dB reserve
Power requirements
Operating voltage 5 VDC +-5%, ripple <50 mVpp
Power consumption 3.5 W
Current consumption 650 mA
Ambient conditions
Operating temperature 0 ºC to +50 ºC
Storage/transport temperature -20 ºC to +80 ºC
Relative humidity (non-condensing) 10% to 90%
Mechanical construction
Mounting stand-alone unit in an aluminium section housing
Dimensions (W x H x D) 129 x 34.9 x 130.7 mm
Weight 340 g
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) contact discharge: 4 kV, air discharge: 8 kV
EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst) power line: 2 kV
EN 61000-4-5 surge voltage power line: 1 kV (line/line)
EMC emitted immunity
EN 55022 EN 55022 limit class B
Scope of delivery and accessories
Scope of delivery ready-to-connect transmitter, plug-in power supply PSW 5-24, HD Sub connecting cable, operating instructions